目前,QuantiFERON-TBGoldin-tubetest(QFT-IT)试验是结核病诊断的方法之一,其是针对T淋巴细胞对早期分泌靶抗原6(ESAT-6)和培养分泌蛋白10(CFP-10)的反应而进行的全血γ-干扰素(γ-IFN)释放试验。来自哥本哈根大学国际卫生、免疫及微生物学系的MichalaV.Rose等人在一个地方性医疗机构中,对儿童和成人中使用QuantiFERON microtu

目前,QuantiFERON-TBGoldin-tubetest(QFT-IT)试验是结核病诊断的方法之一,其是针对T淋巴细胞对早期分泌靶抗原6(ESAT-6)和培养分泌蛋白10(CFP-10)的反应而进行的全血γ-干扰素(γ-IFN)释放试验。来自哥本哈根大学国际卫生、免疫及微生物学系的MichalaV.Rose等人在一个地方性医疗机构中,对儿童和成人中使用QuantiFERON microtube(QFT-MT)(仅需0.9ml血液)和QuantiFERON-TB Gold in-tubetest(QFT-IT)(3ml血液)诊断结核病(TB)的效果作了比较。结果于2013年4月1日发表在EuropeanRespiratoryJournal。研究人员发现QFT-MT测试所需血液量仅为QFT-IT所需血液量的不到三分之一,且结果非常可靠。由此认为QFT-MT可有效诊断儿童结核病。

研究人员在152名疑似TB的儿童和87名确诊TB的成人中,对QFT-IT与2类QFT-MT的浓度(QFT-MTA和B)进行比较。对阳性和不确定结果的比例、干扰素(IFN)-γ反应、批间分析一致性及其灵敏度进行评估。

研究人员发现其不确定结果的比例、IFN-γ及可比灵敏度的水平基本类似。所有儿童(QFT-ITvs.QFT-MTA:85%,K=0.44和QFT-ITvs.QFT-MTB:88%,k=0.50)和成人(QFT-ITvs.QFT-MTA:88%,K=0.50和QFT-ITvs.QFT-MTB:89%,k=0.49)的批间分析一致性均为中度。QFT-IT、QFT-MTA和QFT-MTB诊断成人TB灵敏度分别为83%、86%和88%,但其对确诊和高度疑似TB患儿的诊断灵敏度则相对较低(23%、18%和19%)。

研究人员认为QFT-MT测试所需血液量仅为QFT-IT所需血液量的不到三分之一,且结果非常可靠。减少的血液用量对研究和小儿TB的进一步诊断可能会非常有用。重病儿童患者γ-干扰素释放试验的灵敏度低和不确定率高,同时其在特有设定时的免疫力不成熟或受损,值得进一步研究。

结核相关的拓展阅读:


Evaluation of QuantiFERON microtube, using 0.9 mL blood, for diagnosing tuberculosis infection.
Abstract
The performance of QuantiFERON microtube (QFT-MT), using 0.9 mL blood, and QuantiFERON-TB Gold in-tube test (QFT-IT) (3 mL blood), for diagnosing tuberculosis (TB) was compared in children and adults in an endemic setting. In 152 children with suspected TB and 87 adults with confirmed TB, QFT-IT was compared with two QFT-MT concentrations (QFT-MT A and B). Proportions of positive and indeterminate results, interferon (IFN)-γ responses, interassay agreement and sensitivity were assessed. We found similar proportions of indeterminate results, levels of IFN-γ and comparable sensitivity. The interassay agreement was moderate in all children (QFT-IT versus QFT-MT A: 85%, k=0.44 and QFT-IT versus QFT-MT B: 88%, k=0.50) and adults (QFT-IT versus QFT-MT A: 88%, k=0.50 and QFT-IT versus QFT-MT B: 89%, k=0.49). Sensitivity was low (QFT-IT 23%, QFT-MT A 18% and B 19%) in children with confirmed or highly probable TB compared with adults (83%, 86% and 88%, respectively). The QFT-MT test can be reliably performed using less than one-third of the blood volume used in QFT-IT. The reduced volume may be useful for research and future diagnosis of paediatric TB. The poor sensitivity and high indeterminate rate of both IFN-γ release assays in severely ill children, with immature or impaired immunity in an endemic setting, warrants further investigations.

版权声明:
本网站所有内容来源注明为“梅斯医学”或“MedSci原创”的文字、图片和音视频资料,版权均属于梅斯医学所有。非经授权,任何媒体、网站或个人不得转载,授权转载时须注明来源为“梅斯医学”。其它来源的文章系转载文章,或“梅斯号”自媒体发布的文章,仅系出于传递更多信息之目的,本站仅负责审核内容合规,其内容不代表本站立场,本站不负责内容的准确性和版权。如果存在侵权、或不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
在此留言
评论区 (1)
#插入话题
  1. [GetPortalCommentsPageByObjectIdResponse(id=1253868, encodeId=370712538688f, content=<a href='/topic/show?id=f30ae86297d' target=_blank style='color:#2F92EE;'>#结核#</a>, beContent=null, objectType=article, channel=null, level=null, likeNumber=36, replyNumber=0, topicName=null, topicId=null, topicList=[TopicDto(id=78629, encryptionId=f30ae86297d, topicName=结核)], attachment=null, authenticateStatus=null, createdAvatar=, createdBy=4dfa37, createdName=huhuaidong387, createdTime=Sun May 05 00:17:00 CST 2013, time=2013-05-05, status=1, ipAttribution=)]