Single lag screw and reverse distal femur locking compression plate for concurrent cervicotrochanteric and shaft fractures of the femur: biomechanical study validated with a clinical series

Jitprapaikulsarn, S; Chantarapanich, N; Gromprasit, A; Mahaisavariya, C; Patamamongkonchai, C

Chantarapanich, N (corresponding author), Kasetsart Univ, Fac Engn Sriracha, Dept Mech Engn, Sriracha, Chonburi, Thailand.

EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021; 31 (6): 1179

Abstract

BackgroundThe optimal surgical management of concurrent cervicotrochanteric and shaft fractures of the femur has not been consensual. The authors inve......

Full Text Link